ECan survey puts 38 of 358 Canterbury wells above the nitrate limit
Environment Canterbury (ECan) sampled 358 wells in its 2025 Annual Groundwater Quality Survey, and 38 of them had nitrate-nitrogen above the drinking water limit of 11.3mg/L. That’s 10.6%, which ECan describes as similar to the 10% it recorded in 2024.
E. coli moved the other way, with detections in 23 wells, down from 49 in 2024. A one-off check for lead found very low levels in some samples and no well over the drinking water standard.
The wells are a mix of public and privately owned, and ECan water and land science manager Dr Elaine Moriarty told RNZ they aren’t all used for drinking water. ECan’s report on the 2024 survey says its samples indicate the quality of untreated source water, and that monitoring drinking water supplies is the supplier’s job.
Most long-term wells are still rising
Among wells assessed for long-term trends, 59% showed rising nitrate over the past decade, 24% falling and 17% no clear trend. In the 2024 survey, the split across 301 wells with enough data was 62% rising, 20% falling and 18% no trend.
ECan says higher concentrations usually sit in areas with more intensive land use. More than half of the shallow groundwater samples assessed in areas connected to rivers and streams were above the 2.4mg/L surface water bottom line, which ECan says could contribute to ecological impacts.
Moriarty says the results can run a long way behind what’s happening on the land. “In parts of Canterbury with deep groundwater the water we sample today may have entered the ground many years ago.”
Federated Farmers president Colin Hurst told RNZ that farmers are reducing stocking rates, planting plantain, applying fertiliser more precisely and fencing off waterways. Roger Lincoln, DairyNZ’s general manager of policy and government relations, says Canterbury dairy farms have cut nitrogen loss per hectare by 30% over the past decade. He also points to a four-year Lincoln University farmlet trial, where pastures averaging 17% plantain reduced annual nitrate leaching by around 33% while maintaining milk production.
Greenpeace programme director Niamh O’Flynn says voluntary industry measures have failed, and the organisation wants dairy expansion stopped. ECan councillor Genevieve Robinson says the council’s own target is for at least 50% of monitored sites to show decreasing trends, and she’s asking what changes when targets are missed. In September 2026, the council declared its 2025 nitrate emergency over and voted 9-7 against further work on funding treatment for private supplies.
What the limit covers
The limit sits in the 2022 drinking water standards regulations as a short-term value of 50mg/L nitrate, or 11.3mg/L as nitrate-nitrogen. Waimakariri District Council’s guide for well owners tells them to check which unit their results use.
ECan’s 2024 report says the value was set to protect bottle-fed infants against blue baby syndrome, and that the Ministry of Health recommends applying it to protect bottle-fed babies under six months and pregnant women. The ministry is also reviewing the research on nitrate’s health effects in drinking water, and expects to release that review by the end of 2026.
Bores, consents and who’s responsible
Under the Water Services Act 2021, a stand-alone home with its own supply is a domestic self-supply, and a shared domestic supply serves no more than 25 people in domestic dwellings. The Water Services Authority, Taumata Arowai, says neither has specific responsibilities under the Act, though it recommends managing the risks the way a registered supplier would.
That changes once the water reaches a business or the public. The regulator says a supply serving a public, commercial or community facility, such as a café or community hall, has legal obligations even at 25 people or fewer. The Act’s own examples of what isn’t a shared domestic supply include a home and a neighbouring fruit packhouse, and 40 homes on the same street.
Waimakariri’s guide says the council confirms a potable water source through the resource consent for a subdivision and the building consent for a new dwelling, but only at the time the consent is issued. It recommends connecting to a public supply where that’s feasible, and testing when buying a property or drilling a new well.
ECan recommends private well owners test for E. coli every three months, nitrate once a year, and heavy metals and organic chemicals every three years, with extra tests after heavy rain or flooding. Taumata Arowai lists accredited laboratories, which supply the sampling kits.
For high nitrate, the Waimakariri guide points to reverse osmosis or ion exchange. The Otago Daily Times reported ECan staff’s indicative figures for household nitrate treatment at $3000 to $5000 for a whole-house system or $1000 to $2000 for an under-sink unit, plus annual maintenance.